Tampa Monthly Tests and Inspections for Portable Fire Extinguishers

It's suggested by NFPA 10 standards and codes for portable fire extinguishers to perform monthly tests and inspections on your portable fire extinguishers which includes some of the following procedures:

Tampa Classes of Fire

Monthly Fire Extinguisher Tests and Inspections Required by OSHA in Tampa

The following is an excerpt from OSHA regarding residential, commercial and industrial fire extinguisher tests, inspections, refills, recharges, hydrostatic testing, monthly inspections, annual inspections, and 6 & 12 year hydrostatic tests, inspections and required service maintenance.

1910.157(e)(2)

Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.

1910.157(e)(2)

Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.
1910.157(e)(3)
The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.
1910.157(e)(4)
The employer shall assure that stored pressure dry chemical extinguishers that require a 12-year hydrostatic test are emptied and subjected to applicable maintenance procedures every 6 years. Dry chemical extinguishers having non-refillable disposable containers are exempt from this requirement. When recharging or hydrostatic testing is performed, the 6-year requirement begins from that date.
..1910.157(e)(5)

1910.157(e)(5)
The employer shall assure that alternate equivalent protection is provided when portable fire extinguishers are removed from service for maintenance and recharging.
1910.157(f)
Hydrostatic testing.
1910.157(f)(1)
The employer shall assure that hydrostatic testing is performed by trained persons with suitable testing equipment and facilities.
1910.157(f)(2)
The employer shall assure that portable extinguishers are hydrostatically tested at the intervals listed in Table L-1 of this section, except under any of the following conditions:
1910.157(f)(2)(i)
When the unit has been repaired by soldering, welding, brazing, or use of patching compounds;
1910.157(f)(2)(ii)
When the cylinder or shell threads are damaged;
1910.157(f)(2)(iii)
When there is corrosion that has caused pitting, including corrosion under removable name plate assemblies;
1910.157(f)(2)(iv)
When the extinguisher has been burned in a fire; or
1910.157(f)(2)(v)
When a calcium chloride extinguishing agent has been used in a stainless steel shell.
1910.157(f)(3)
In addition to an external visual examination, the employer shall assure that an internal examination of cylinders and shells to be tested is made prior to the hydrostatic tests.
TABLE L-1
Type of extinguishers Test interval (years)
Soda acid (soldered brass shells) (until 1/1/82)
Soda acid (stainless steel shell)
Cartridge operated water and/or antifreeze
Stored pressure water and/or antifreeze
Wetting agent
Foam (soldered brass shells) (until 1/1/82)
Foam (stainless steel shell)
Aqueous Film Forming foam (AFFF)
Loaded stream
Dry chemical with stainless steel
Carbon Dioxide
Dry chemical, stored pressure, with mild steel, brazed brass or aluminum shells
Dry chemical, cartridge or cylinder operated, with mild steel shells
Halon 1211
Halon 1301
Dry powder, cartridge or cylinder operated with mild steel shells
(1)
5
5
5
5
(1)
5
5
5
5
5
12

12
12
12
12
1Extinguishers having shells constructed of copper or brass joined by soft solder or rivets shall not be hydrostatically tested and shall be removed from service by January 1, 1982. (Not permitted)
..1910.157(f)(4)

1910.157(f)(4)
The employer shall assure that portable fire extinguishers are hydrostatically tested whenever they show new evidence of corrosion or mechanical injury, except under the conditions listed in paragraphs (f)(2)(i)-(v) of this section.
1910.157(f)(5)
The employer shall assure that hydrostatic tests are performed on extinguisher hose assemblies which are equipped with a shut-off nozzle at the discharge end of the hose. The test interval shall be the same as specified for the extinguisher on which the hose is installed.
1910.157(f)(6)
The employer shall assure that carbon dioxide hose assemblies with a shut-off nozzle are hydrostatically tested at 1,250 psi (8,620 kPa).
1910.157(f)(7)
The employer shall assure that dry chemical and dry powder hose assemblies with a shut-off nozzle are hydrostatically tested at 300 psi (2,070 kPa).
1910.157(f)(8)
Hose assemblies passing a hydrostatic test do not require any type of recording or stamping.
1910.157(f)(9)
The employer shall assure that hose assemblies for carbon dioxide extinguishers that require a hydrostatic test are tested within a protective cage device.
..1910.157(f)(10)

1910.157(f)(10)
The employer shall assure that carbon dioxide extinguishers and nitrogen or carbon dioxide cylinders used with wheeled extinguishers are tested every 5 years at 5/3 of the service pressure as stamped into the cylinder. Nitrogen cylinders which comply with 49 CFR 173.34(e)(15) may be hydrostatically tested every 10 years.
1910.157(f)(11)
The employer shall assure that all stored pressure and Halon 1211 types of extinguishers are hydrostatically tested at the factory test pressure not to exceed two times the service pressure.
1910.157(f)(12)
The employer shall assure that acceptable self-generating type soda acid and foam extinguishers are tested at 350 psi (2,410 kPa).
1910.157(f)(13)
Air or gas pressure may not be used for hydrostatic testing.
1910.157(f)(14)
Extinguisher shells, cylinders, or cartridges which fail a hydrostatic pressure test, or which are not fit for testing shall be removed from service and from the workplace.
1910.157(f)(15)(i)
The equipment for testing compressed gas type cylinders shall be of the water jacket type. The equipment shall be provided with an expansion indicator which operates with an accuracy within one percent of the total expansion or .1cc (.1mL) of liquid.
1910.157(f)(15)(ii)
The equipment for testing non-compressed gas type cylinders shall consist of the following:
..1910.157(f)(15)(ii)(A)

1910.157(f)(15)(ii)(A)
A hydrostatic test pump, hand or power operated, capable of producing not less than 150 percent of the test pressure, which shall include appropriate check valves and fittings;
1910.157(f)(15)(ii)(B)
A flexible connection for attachment to fittings to test through the extinguisher nozzle, test bonnet, or hose outlet, as is applicable; and
1910.157(f)(15)(ii)(C)
A protective cage or barrier for personal protection of the tester, designed to provide visual observation of the extinguisher under test.
1910.157(f)(16)
The employer shall maintain and provide upon request to the Assistant Secretary evidence that the required hydrostatic testing of fire extinguishers has been performed at the time intervals shown in Table L-1. Such evidence shall be in the form of a certification record which includes the date of the test, the signature of the person who performed the test and the serial number, or other identifier, of the fire extinguisher that was tested. Such records shall be kept until the extinguisher is hydrostatically retested at the time interval specified in Table L-1 or until the extinguisher is taken out of service, whichever comes first.
1910.157(g)
Training and education.
1910.157(g)(1)
Where the employer has provided portable fire extinguishers for employee use in the workplace, the employer shall also provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting.
1910.157(g)(2)
The employer shall provide the education required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter.
1910.157(g)(3)
The employer shall provide employees who have been designated to use fire fighting equipment as part of an emergency action plan with training in the use of the appropriate equipment.
1910.157(g)(4)
The employer shall provide the training required in paragraph (g)(3) of this section upon initial assignment to the designated group of employees and at least annually thereafter.

Fire Service Pro © Fire Protection Company Websites

Fire Extinguisher Companies
Fire Protection Companies in Florida

Fire Protection Companies in the State of Florida

Florida Fire Protection Companies

Fire Protection Companies in the State of Florida

Alafaya, FL Fire Protection Jacksonville, FL Fire Protection
Apopka, FL Fire Protection Kendall, FL Fire Protection
Boca Raton, FL Fire Protection Lakeland, FL Fire Protection
Brandon, FL Fire Protection Largo, FL Fire Protection
Cape Coral, FL Fire Protection Melbourne, FL Fire Protection
Clearwater, FL Fire Protection Miami, FL Fire Protection
Coral Gables, FL Fire Protection Miramar, FL Fire Protection
Coral Springs, FL Fire Protection Orlando, FL Fire Protection
Davie, FL Fire Protection Pembroke Pines, FL Fire Protection
Daytona Beach, FL Fire Protection Plantation, FL Fire Protection
Fort Lauderdale, FL Fire Protection St. Petersburg, FL Fire Protection
Gainesville, FL Fire Protection Sunrise, FL Fire Protection
Hialeah, FL Fire Protection Tallahassee, FL Fire Protection
Hollywood, FL Fire Protection Tampa, FL Fire Protection

Fire Protection Engineering and Design Company for the State of Florida

Staley Consulting Inc.
www.fireproengineer.com

Staley Consulting Inc. designs and engineers all fire protection systems complete with Drafts, Drawings, Blueprints, AUTOCAD and 3-D designs that may be required to pass permits and inspections conducted by the State Fire Marshall, OSHA, Insurance Companies, Health Code Compliance and Fire Code Compliance Agencies. The addition of a Fire Protection P.E. to the A/E team allows the architect to show the client that questions and concerns regarding fire protection will be addressed professionally.

Our team has years of practical experience, carry NICET Level III Certifications, AUTOCAD Engineers, P.E. and Degrees in Computer Assisted Design and Drafting.

We specialize in design and engineering of wet, dry, deluge, preaction, special hazard sprinkler systems, fire protection systems, fire sprinkler systems, fire alarm systems, fire hydrants, fire pumps, standpipes, backflow preventers, fire suppression systems, restaurant kitchen suppression systems and the full fire protection systems that may be required for hospitals, schools, museums, libraries, churches, malls, stores, gas stations, fuel dispensing companies, industrial plants, factories, commercial and/or residential buildings.

We have designed fire protection systems for Universal Studios at Universal Orlando Resort ®, Walt Disney World ® MGM Studios, Westin Grand Imagine, The Paramount in Orlando FL, Cape Canaveral Air Force Station, United States Navy, United States Air Force, United States Army, City of Clermont (Florida), Dillard High School (Broward County, Florida), Daytona Beach College, 101 Eola, Publix, Mirabay Clubhouse, Oviedo Gymnasium & Aquatic Center, JetBlue, Verizon Wireless, Orlando Regional Medical Center, Saint Katharine Drexel Catholic Church, Seventh Day Adventist Church, Sandestin Luau, Habana Grill, Charley's Steakhouse to name projects.

We Carry the following Fire Protection Engineering Classifications in Florida

Assembly Occupancy Aviation Education Entertainment Government Industrial
Medical Military Mixed Use Office Religious Assemblies Residential Restaurants
Retail            
Design and Engineering the following Fire Protection Systems
Fire Protection Systems Fire Sprinkler Systems Fire Hydrants Fire Suppression Systems Standpipe Fire Sprinkler Systems Water Based Automatic Fire Sprinklers
  • Prepare Design Drawings
  • Hydraulic Calculations
  • Communicate with Officials on Local Fire Codes
  • Prepare Fire Protection Specifications
  • Fire Code Research
  • Field Site Visits
  • Construction Administration
  • Punch Lists
  • Answering RFI's
  • Provide Working Drawings Per NFPA 13
  • Shop Drawings & Review
  • Emergency Signage & Lighting
  • Evacuation Routes
  • Road Turn Arounds
  • Automatic Fire Sprinklers
  • Water Based
  • Standpipe Systems
  • Special Hazards
  • Fire Hydrants
  • Fire Pumps
  • Backflow Preventers
  • Design
  • Flow Testing
  • Determine Availability of Water Supply
  • Engineering
  • Fire Hydrant Testing
  • Restaurant Kitchen Suppression Systems
    • Restaurant kitchen hood suppression systems
  • Auto Body or Paint Spray Booth Fire Suppression Systems
  • Data Centers Fire Suppression Systems
  • Kitchen fire protection systems
  • Clean agent fire suppression systems
    • Carbon dioxide fire suppression systems
    • Data centers, computer rooms, file storage facilities
  • Wet standpipe fire sprinklers
  • Dry standpipe fire sprinklers
  • Combined standpipe fire sprinklers
  • Standpipe hose connections
  • Temporary Standpipes
  • Standpipe fire sprinklers
  • Wet pipe automatic fire sprinklers
  • Dry pipe automatic fire sprinklers
  • Deluge automatic fire sprinklers
  • Combined automatic fire sprinklers
  • Pre-Action automatic fire sprinklers

Fire Protection Companies in the United States

Fire Protection Companies in the United States

Baltimore, MD Buffalo, NY Las Vegas, NV Markham, Canada Orange County, CA
Sacramento, CA San Diego, CA San Diego, CA Tampa, FL Toronto, Canada
Los Angeles, CA Fire Protection Engineering     Vaughan, Canada

 

Contact Us to Build a Fire Protection Website in Your City.